Comprehensive medicine stability testing chamber
Scope of use:
A scientific method is used to create an environment of temperature, humidity and illumination required for medicine failure evaluation, which is suitable for pharmaceutical enterprises to experiment on the influencing factors of medicine and new medicines.
Features:
Adopt imported high-quality parts to ensure long-term continuous operation and stable and reliable performance.
High resolution dedicated touch screen temperature and humidity controller, excellent man-machine interface.
Standard three-level authority, audit trail, to ensure data authenticity and consistency.
Imported high-precision humidity sensor, with small drift and no maintenance.
Standard micro printer can print temperature and humidity curves and data in real time.
Electronic records are standard, and the data of electronic records in the controller can be exported.
RS485 interface is standard, and single or multiple instruments can be monitored by computer through networking.
Mobile phone short message alarm is standard, and Internet of Things technology is adopted, so SIM card is not required.
The visual observation window of the gate is provided with a key lock to prevent irrelevant personnel from opening the door and affecting the experiment.
Two sets of imported fully enclosed heat-resistant compressors have low noise and long service life.
Meet the relevant test requirements of FDA, ICH, JJF-2019 and national pharmacopoeia.
Meet the low temperature test of 40℃/20%RH and 25℃/40%RH for special drugs such as infusion.
Manufacturing execution standard (technical conditions): refer to GB/T10586-2006.
Technical Parameter:
Model | QF-150GSD-2T | QF-250GSD-2T | QF-500GSD-2T | QF-800GSD-2T | QF-1000GSD-2T |
Volume (L) | 150 | 250 | 500 | 800 | 1000 |
Temperature range | 0-65℃( No light ) / 15-65℃( There is light ) |
Temperature fluctuation | ≤±0.5 ℃ |
Temperature deviation | ≤±1 ℃ |
Humidity range | 15-95%R.H |
Humidity deviation | ≤±3% R.H |
Intensity of illumination | 10-8000lux |
Illumination deviation | ≤±500lux |
Near ultraviolet illumination | 80-200μw/cm2 |
Humidification method | electric steam heating (external humidification, more energy-saving, avoids secondary pollution, and is more convenient for maintenance) |
Working environment temperature | +5-40℃ |
Liner material | mirror stainless steel |
Shell material | steel plate sprayed |
Safety devices | independent overload protection, independent studio over-temperature protection, compressor overload protection, overpressure protection, water blockage protection, water shortage protection |
Working power supply | AC220V 50HZ |
Installation power (W) | 1300 | 1600 | 2400 | 2600 | 2600 |
Plates | 2 | 3 | 4 | 4 | 4 |
Hotline: +86 400 887 8805
Company website: www.qinfutech.com
Email: qinfutech@126.com
Beijing Qinfu Technology Co., Ltd. (North China): Manager Bao: 18514485008
Shanghai Qinfu Technology Co., Ltd. (East China): Manager Qian: 15021305696
Guangzhou Qinfu Technology Co., Ltd. (South China): Manager Zhao: 18796797820
Chongqing Qinfu Technology Co., Ltd. (Southwest China): Manager Ran: 13996167363
Hunan Qinfu Technology Co., Ltd. (Central China): Manager Yang: 15021307892