Walk-in Medicine Stability Testing Chamber


  • 价格:Negotiated
  • 编号:QF-SD/FD
  • 产地: Shanghai Qinfu
Details
Specification
Parameter

Scope of use:


Use scientific methods to create a long-term temperature and humidity environment required for drug failure evaluation.

It is convenient for storing large quantities of drugs and conducting long-term moisture resistance cycle tests.



Features:


1. Use imported high-quality components to ensure long-term continuous operation and stable and reliable performance.

2. Original imported special touch screen temperature and humidity controller, with clear and intuitive display, stable control and easy operation.

3. Imported high-precision humidity sensor with high sensitivity, small drift and no maintenance required.

4. Equipped with a micro printer to print temperature and humidity curves and data in real time.

5. Optional monitoring and recording system that complies with FDA standards, double recording makes data safer.

6. The standard RS485 interface can be used to control one or more instruments through a computer and to record and back up the control data in real time.

7. Standard configuration of SMS alarm for temperature and humidity deviations and power outages. One mobile phone card can be used to monitor the operating status of multiple instruments.

8. Equipped with a door key lock and anti-reverse locking device to prevent irrelevant personnel from affecting the experiment, and people can exit the laboratory safely.

9. The circulating water supply system solves the problems of frequent water addition, water tank cleaning and no drainage pipes, greatly delaying the problem of bacteria growth in the water system.

10. Imported fully enclosed heat-resistant compressor, adopts environmentally friendly refrigeration, low noise, long life, and can be designed according to the site conditions.

Energy saving and emission reduction (one for backup and one for use).

11. Meet the accelerated, long-term, intermediate and high temperature and high humidity tests in the relevant requirements of FDA, ICH, JJF-2019 and the National Pharmacopoeia.

12. Provide IQ, PQ and OQ verification data that meet international standards.

13.Manufacturing implementation standards (technical conditions): refer to GB/T 10586-2006.



Technical Parameters


model

LHH-15000SDP/FD

LHH-30000SDP/FD

LHH-40000SDP/FD

LHHP- 80000SDP/FD

LHHP- *** SDP/FD

Volume (M3)

15

30

40

80

5-200 Customized

temperature range

20~60℃

Temperature fluctuation

≤±0.5℃

Temperature deviation

≤±1℃ (uniformity ≤2℃)

Humidity range

40~90%R.H

Humidity deviation

≤±3%RH (uniformity ≤5%RH)

Humidification method

Electric steam humidifier

Working temperature

+5~40℃

Liner material

304 stainless steel

shell material

Cold rolled steel plate spraying

safety devices

Power overload, independent over-temperature, compressor overload, over-pressure, water blockage, water shortage protection

Working power supply

AC220V±10% 50HZ

AC220V±10% 50HZ

AC220V or 380V±10% 50HZ

Installation power (W)

4500

5500

4500

5500

Determined by user volume

Carrier

4pcs/4layers

8pcs/4 layers

12pcs/4 layers

24pcs/4 layers

Determined by user volume

Internal dimensions (mm)*

2000X3400X2200

3600X3780X2200

3600X5050X2200

5400X6700X2200

Determined according to the user's site size

Dimensions (mm)*

2200X3600X2400

3800X3980X2400

3800X5250X2400

5600X6900X2400

Determined according to the user's site size

Remark

The operating power is the actual measured data of 40℃ 75% no-load with one compressor turned on; the cargo rack is available in nickel-plated, stainless steel and other options


Note: Dimensions are D x W x H(mm)