Midicine Stability Testing Chamber (Single door)


  • 价格:Negotiated
  • 编号:LHH-SD-3T
  • 产地: Shanghai Qinfu
Details
Specification
Parameter

Scope of use:

The LHH-SD-3T series products can provide a stable and reliable temperature and humidity environment. They are specially used for drug stability testing in the pharmaceutical industry to check whether the drugs have reached their expiration date. They are equipped with an electronic record system with three levels of authority and audit tracking, complying with North American FDA 21CFR PART 11 regulations and suitable for CGMP certified users.


Features:

1. Use imported high-quality components to ensure long-term continuous operation and stable and reliable performance.

2. High-resolution dedicated touch screen temperature and humidity controller, excellent human-machine interface.

3. Standard three-level authority and audit tracking function to ensure data authenticity and consistency.

4. Imported high-precision humidity sensor with small drift and no maintenance required.

5. The standard micro printer can print temperature and humidity curves and data in real time.

6. Electronic records are standard and can export electronic record data in the controller.

7. Standard RS485 interface, which can be connected to the Internet and monitor single or multiple instruments through a computer.

8. Mobile phone SMS alarm is standard, and one mobile phone card can manage multiple devices.

9. The doors open to the left and right, and the outer door is equipped with a lock to prevent unauthorized personnel from opening the door and affecting the test.

10. Two sets of imported fully enclosed heat-resistant compressors with low noise and long service life.

11. The glass inner door allows for easy observation of the internal sample placement.

12. Meet the relevant test requirements of FDA, ICH, JJF-2019 and national pharmacopoeia.

13. Circulating water supply system greatly delays the problem of bacteria growth in the water system. External humidification system avoids secondary cross contamination

14. Meet the low humidity test of 40℃, 20%RH and 25℃, 40%RH for special drugs such as large infusion.

15.Manufacturing implementation standards (technical conditions): refer to GB/T 10586-2006.


Technical Parameters:

model

LHH-80SD-3T

LHH-150SD-3T

LHH-250SD-3T

LHH-500SD-3T

LHH-800SD-3TLHH-1000SD-3TLHH-1500SD-3TLHH-2000SD-3T

Volume (L)

80

150

250

500

800100015002000

temperature range

0~65℃

Temperature fluctuation

≤±0.5℃

Temperature deviation

≤±1℃ (uniformity ≤2℃)

Humidity range

15~95%R.H

Humidity deviation

≤±3%RH (uniformity ≤5%RH)

Humidification method

Electric steam humidifier (external humidification system to avoid secondary cross contamination, simple and convenient water line maintenance)

Working temperature

+5~40℃

Liner material

304 mirror stainless steel

shell material

Cold rolled steel plate spraying

safety devices

Power overload protection, independent studio over-temperature protection, compressor overload, overpressure protection, water blockage, water shortage protection

Working power supply

AC220V±10% 50HZ

Installation power (W)

650

1200

1400

2000

2200220030003000

Carrier Plate

2 layer

2 layer

3 layers

4th floor

4th floor

4th floor

5th floor

5th floor

Internal dimensions (mm)

320X500X500

500X530X600

500X530X1000

800X6500X950

500X1300X1230

540X1400X1330

700X1610X1330

900X1670X1330

Dimensions (mm)

870X660X1110

1040X690X1210

1040X690X1530

1350X810X1560

830X1460X1850

870X1560X1950

1030X1770X1950

1220X1830X1950

Note: Dimensions are D x W x H(mm)